DVR 2proVacuum gauge
Overview
- improved functionality within the navigation menu helps to save energy and to increase the life cycle of the battery
- large, graphical analog display with digital measuring values alows to detect tendencies and makes it easier to readout precisely
- pressure unit user-selectable in mbar, hPa or Torr prevents unnecessary conversions
- different vacuum connections and the additional support rod allow the use in almost every laboratory application
- chemical resistant materials for wetted parts together with the capacitive ceramic diaphragm pressure sensor provide excellent long-term stability and accuracy
Vacuum gauge in action
The DVR 2pro is a fully electronic, versatile vacuum gauge for the measuring range from atmospheric pressure to 1 mbar. All wetted parts are made from enhanced chemical resistant material which allows the use under very rough laboratory conditions. The high accuracy and the large graphical display from the DVR 2 have also been carried forward for the “pro” version. One of the main enhancements is the power supply with a normal 9 V Alkaline battery. The new battery slot at the back of the gauge allows for easy replacement of the battery. A wider range of connection parts provide a great range of connection flexibility for laboratory use.
Technical data and graphs
Upper measuring limit in mbar/hPa | 1060 mbar | |
Upper measuring limit in torr | 795 torr | |
Lower measuring limit in mbar/hPa | 1 | |
Lower measuring limit in torr | 1 torr | |
Measurement principle | Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure | |
Accuracy of measurement | < +- 1 mbar/hPa/torr / +- 1 digit (after adjustment, constant temp.) mbar/hPa/torr | |
Temperature coefficient | < 0.15 mbar/hPa/0.11 torr /K mbar/hPa/torr /K | |
Vacum connection | Small flange KF DN 16, PTFE tubing connection 10/8 mm, hose nozzle DN 6/10 mm | |
Lower ambient temperature (storage) | -10 °C | |
Upper ambient temperature (storage) | 60 °C | |
Lower ambient temperature (operation) | 10 °C | |
Upper ambient temperature (operation) | 40 °C | |
Max. media temperature for continuous operation | 40 °C | |
Max. media temperature short term | 80 °C | |
Automatic switch-off | User-selectable: 1-600 min (default 5 min) or continuous operation min | |
Measurement cycle | User-selectable: Automatic or 1 x per 3s, 1 x per 1s, 3 x per 1s | |
Material of outer housing | Robust plastic housing with good chemical resistance | |
Protection class IEC 60529 | IP 40 | |
Protection class front side IEC 60529 | 6 | |
Power supply | 9 V battery | |
Weight | 0.4 kg | |
Dimension L in mm | 115 mm | |
Dimension B in mm | 115 mm | |
Dimension H in mm | 90 mm | |
Vacuum sensor | Integr. | |
Typical battery lifetime | 4.000 h, stand-by: 30.000 h h | |
NRTL certification | No | |
Items supplied | Vacuum gauge complete with integrated vacuum sensor, including battery 9 V alkali-manganese, support rod, connecting parts and manual. |
Downloads
Equipment
-
DN 8 mm, sale per meter Rubber vacuum tubing
- Natural rubber + SBR
- Nominal width DN 8 mm
- Sale per meter
This might also interest you
-
VACUU·VIEW extended Vacuum gauge
- Chemically resistant
- Excellent long-term stability
- Mains powered
VACUU·VIEW Vacuum gauge- Chemically resistant
- Excellent long-term stability
- Mains powered
Vacuum gauge in action
The DVR 2pro is a fully electronic, versatile vacuum gauge for the measuring range from atmospheric pressure to 1 mbar. All wetted parts are made from enhanced chemical resistant material which allows the use under very rough laboratory conditions. The high accuracy and the large graphical display from the DVR 2 have also been carried forward for the “pro” version. One of the main enhancements is the power supply with a normal 9 V Alkaline battery. The new battery slot at the back of the gauge allows for easy replacement of the battery. A wider range of connection parts provide a great range of connection flexibility for laboratory use.
Technical data and graphs
Upper measuring limit in mbar/hPa 1060 mbar Upper measuring limit in torr 795 torr Lower measuring limit in mbar/hPa 1 Lower measuring limit in torr 1 torr Measurement principle Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure Accuracy of measurement < +- 1 mbar/hPa/torr / +- 1 digit (after adjustment, constant temp.) mbar/hPa/torr Temperature coefficient < 0.15 mbar/hPa/0.11 torr /K mbar/hPa/torr /K Vacum connection Small flange KF DN 16, PTFE tubing connection 10/8 mm, hose nozzle DN 6/10 mm Lower ambient temperature (storage) -10 °C Upper ambient temperature (storage) 60 °C Lower ambient temperature (operation) 10 °C Upper ambient temperature (operation) 40 °C Max. media temperature for continuous operation 40 °C Max. media temperature short term 80 °C Automatic switch-off User-selectable: 1-600 min (default 5 min) or continuous operation min Measurement cycle User-selectable: Automatic or 1 x per 3s, 1 x per 1s, 3 x per 1s Material of outer housing Robust plastic housing with good chemical resistance Protection class IEC 60529 IP 40 Protection class front side IEC 60529 6 Power supply 9 V battery Weight 0.4 kg Dimension L in mm 115 mm Dimension B in mm 115 mm Dimension H in mm 90 mm Vacuum sensor Integr. Typical battery lifetime 4.000 h, stand-by: 30.000 h h NRTL certification No Items supplied Vacuum gauge complete with integrated vacuum sensor, including battery 9 V alkali-manganese, support rod, connecting parts and manual. Downloads
Vacuum gauge DVR 2pro, 1080 - 1 mbar*** Alkaline-Manganese Dioxide-Zinc-Batteries! Not restricted - No dangerous goods transportaccording IATA SP A123 and ADR/RID/IMDG code. ***DVR 2pro Vacuum gaugeEquipment
-
DN 8 mm, sale per meter Rubber vacuum tubing
- Natural rubber + SBR
- Nominal width DN 8 mm
- Sale per meter
This might also interest you
-
VACUU·VIEW extended Vacuum gauge
- Chemically resistant
- Excellent long-term stability
- Mains powered
VACUU·VIEW Vacuum gauge- Chemically resistant
- Excellent long-term stability
- Mains powered