CVC 3000 + VSP 3000, KF DN 25Package fine vacuum control

Overview

  • the CVC 3000 controls vacuum, cooling water and venting to demand
  • intuitive operation with turn-and-tap jog wheel and clear text menus
  • rugged VSP 3000 vacuum sensor made of plastics and ceramics with high chemical resistance, splash-water proof, also for rough operating conditions
  • VSP 3000 with wide measurement range from atmospheric pressure to fine vacuum (10-3 mbar) according to the principle of thermal conduction
  • the in-line solenoid valve is chemically highly resistant (series C)
Articleno. 20635982
On demand

Inquire

Package fine vacuum control in action

The packages enable convenient vacuum control in the fine vacuum range down to 10-3 mbar and consist of a CVC 3000 vacuum controller, a VSP 3000 external Pirani vacuum sensor, a VV-B 15C in-line solenoid valve and all necessary small flange components. VACUUBRAND offers two packages, one with small flanges KF DN 16, suitable, e.g., for the VACUUBRAND RE/RZ 2.5 to RE/RZ 6 rotary vane pumps or our RC 6 Chemistry-HYBRID pump; or select the small flange KF DN 25 version suitable for our RE/RZ 9 to RE/RZ 16 rotary vane pumps. The CVC 3000 runs vacuum processes by control of external vacuum, venting and cooling water valves. In these packages the vacuum control is performed by opening and closing the in-line solenoid valve VV-B 15C. The controller and components are completely self-configuring and automatically checked via VACUU·BUS® communication protocol. ###


Information on the disposal of old devices »

Technical data and graphs

Upper measuring limit in mbar/hPa 1000 mbar
Upper measuring limit in torr 750 torr
Lower measuring limit in mbar/hPa 1 x 10-3
Lower measuring limit in torr 1 x 10-3 torr
Measurement principle Thermal conductivity (Pirani), chemically resistant plastics / ceramics
Accuracy of measurement +- 15% of indicated value in the range 0.01-5 mbar/hPa/torr mbar/hPa/torr
Vacuum sensor VSP 3000
Temperature coefficient < 0.07 mbar/hPa/0.05 torr /K mbar/hPa/torr /K
Vacum connection Small flange KF DN 25 / hose nozzle DN 15 mm
Venting valve No
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 20
Protection class UL50E Type 1
Protection class front side IEC 60529 IP 42
Dimension L in mm 144 mm
Dimension B in mm 124 mm
Dimension H in mm 115 mm
Weight 0.44 kg
Max. current for VACUU BUS (24V DC) 4 A
Cable length connection in m 2 m
Interface RS 232C
NRTL certification Yes
Items supplied Package for fine vacuum control, consisting of: - vacuum controller CVC 3000 (without internal vacuum sensor and venting valve) with VSP 3000 and power supply - in-line solenoid valve VV-B 15C KF DN 25 - T-piece KF DN 25, hose nozzle DN 15 mm (PP), clamping and sealing rings, ready for use, with manual.

Downloads

CVC 3000 + VSP 3000, KF DN 25 Package fine vacuum control
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual vacuum gauge / controller
Manual PDF 17.6 MB 18.8 MB 18.3 MB
Download Download Download

Equipment

This might also interest you

Package fine vacuum control in action

The packages enable convenient vacuum control in the fine vacuum range down to 10-3 mbar and consist of a CVC 3000 vacuum controller, a VSP 3000 external Pirani vacuum sensor, a VV-B 15C in-line solenoid valve and all necessary small flange components. VACUUBRAND offers two packages, one with small flanges KF DN 16, suitable, e.g., for the VACUUBRAND RE/RZ 2.5 to RE/RZ 6 rotary vane pumps or our RC 6 Chemistry-HYBRID pump; or select the small flange KF DN 25 version suitable for our RE/RZ 9 to RE/RZ 16 rotary vane pumps. The CVC 3000 runs vacuum processes by control of external vacuum, venting and cooling water valves. In these packages the vacuum control is performed by opening and closing the in-line solenoid valve VV-B 15C. The controller and components are completely self-configuring and automatically checked via VACUU·BUS® communication protocol. ###


Information on the disposal of old devices »

Technical data and graphs

Upper measuring limit in mbar/hPa 1000 mbar
Upper measuring limit in torr 750 torr
Lower measuring limit in mbar/hPa 1 x 10-3
Lower measuring limit in torr 1 x 10-3 torr
Measurement principle Thermal conductivity (Pirani), chemically resistant plastics / ceramics
Accuracy of measurement +- 15% of indicated value in the range 0.01-5 mbar/hPa/torr mbar/hPa/torr
Vacuum sensor VSP 3000
Temperature coefficient < 0.07 mbar/hPa/0.05 torr /K mbar/hPa/torr /K
Vacum connection Small flange KF DN 25 / hose nozzle DN 15 mm
Venting valve No
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 20
Protection class UL50E Type 1
Protection class front side IEC 60529 IP 42
Dimension L in mm 144 mm
Dimension B in mm 124 mm
Dimension H in mm 115 mm
Weight 0.44 kg
Max. current for VACUU BUS (24V DC) 4 A
Cable length connection in m 2 m
Interface RS 232C
NRTL certification Yes
Items supplied Package for fine vacuum control, consisting of: - vacuum controller CVC 3000 (without internal vacuum sensor and venting valve) with VSP 3000 and power supply - in-line solenoid valve VV-B 15C KF DN 25 - T-piece KF DN 25, hose nozzle DN 15 mm (PP), clamping and sealing rings, ready for use, with manual.

Downloads

CVC 3000 + VSP 3000, KF DN 25 Package fine vacuum control
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual vacuum gauge / controller
Manual PDF 17.6 MB 18.8 MB 18.3 MB
Download Download Download

Equipment

This might also interest you