PC 3003 VARIO selectVARIO® chemistry pumping unit

Overview

  • VACUU·SELECT vacuum controller with graphical user interface and predefined applications simplifies work in the laboratory
  • automatic boiling point detection and adjustment of the vacuum for short process times
  • ideal for evaporation of high-boiling solvents even at low temperatures
  • extraordinary diaphragm life for minimum operational and servicing costs
  • excellent environmental compatibility through low energy consumption and efficient solvent recovery

Ultimate vacuum

0.6 mbar

Ultimate vacuum with gas ballast

1.5 mbar

Max. pumping speed 50 Hz

2.8 m3/h

Articleno. 20738453
On demand

Inquire

VARIO® chemistry pumping unit in action

The PC 3003 VARIO select pumping unit precisely controls the vacuum level in order to achieve unparalleled process control. With its high pumping speed and deep ultimate vacuum, this pump is suitable for demanding applications with high boiling point solvents in low temperature conditions. The integrated VACUU·SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run fully automated distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, the VACUU·SELECT controller continuously detects the boiling point and automatically adjusts the vacuum process as necessary. And the VARIO control algorithm maintains the desired vacuum level without running the motor faster than necessary. This prevents bumping and foaming, makes the pump whisper quiet, and extends maintenance intervals. The inlet separator, made of glass with a robust protective coating, prevents particles and liquid droplets from entering the pump, preventing damage and extending pump life. And the exhaust vapor condenser allows for nearly complete recovery of solvents when used with a chilled water line or recirculating chiller for economical recycling and environmental protection. Typical applications are all evaporation processes. They can be run fully automatically by the integrated vacuum controller CVC 3000 resulting in both shorter process times and extra sensitivity at the same time. The excellent ultimate vacuum allows even high boiling solvents to evaporate at low temperatures. The VARIO® control ensures high process reliability through prevention of superheating or foaming. It detects boiling pressures of solvents fully automatically and adapts continuously the vacuum conditions to changing process parameters. All this without any need of parameter input or the use of a solvent library. In many other applications - like in local vacuum networks - the VARIO® control offers a significant advantage by supplying always the appropriate pumping speed. The VACUU·BUS® interface facilitates an user-friendly configuration of even complex vacuum installations.


Information on the disposal of old devices »
 

Technical data and graphs

Max. pumping speed 50 Hz 2.8 m3/h Select diagram
Max. pumping speed 60 Hz 1.65 cfm
Ultimate vacuum 0.6 mbar / 0.45 torr
Ultimate vacuum with gas ballast 1.5 mbar / 1.12 torr
Number of heads 4
Number of stages 4
Vacuum controller VACUU·SELECT
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Max. outlet pressure (abs.) 1.1 bar
Inlet connection Hose nozzle DN 8-10 mm
Outlet connection Hose nozzle DN 8-10 mm
Coolant connection 2 x hose nozzle DN 6-8 mm
Rated motor power 0.53 kW
Protection class IEC 60529 IP 20
Dimension L in mm 419 mm
Dimension B in mm 243 mm
Dimension H in mm 457 mm
Weight 21.1 kg
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) 43 dBA
NRTL certification No
Items supplied Pumping unit completely mounted, ready for use, with manual.
Rated mains voltage range 1 100-120 V
Mains frequency 1 50-60 Hz
Interface Ethernet (RJ45): Modbus TCP / USB (Type A): Data transfer, software update, RS-232 (additional adapter required)

vac_pumpingspeedm3 für Zoom klicken

Max. pumping speed 50 Hz

vac_pumpingcurve50 für Zoom klicken

Pump down graph 50 Hz (10 l volume)

Downloads

VARIO chemistry pumping unit,PC 3003 VARIO select, 100-120V / 50-60Hz,US mains cable
PC 3003 VARIO select VARIO® chemistry pumping unit
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual vacuum gauge / controller
Manual PDF 17.5 MB 17.4 MB 17.4 MB 17.5 MB 17.4 MB 17.5 MB 17.4 MB 17.8 MB 17.5 MB 17.5 MB 17.4 MB 17.5 MB 17.5 MB 17.3 MB
Download Download Download Download Download Download Download Download Download Download Download Download Download Download
Manual interface
Manual PDF 1.8 MB 1.8 MB
Download Download
Manual vacuum pump
Manual PDF 15.3 MB 15.5 MB 15.3 MB 15.3 MB 15.2 MB 15.3 MB 15.3 MB 15.3 MB 15.3 MB 15.3 MB 15.3 MB 15.2 MB
Download Download Download Download Download Download Download Download Download Download Download Download
Manual function extension
Manual PDF 11.6 MB 11.4 MB
Download Download
Brochure
Brochure PDF 2 MB 2 MB
Download Download
Technical data sheet
Data sheet PDF 3.2 MB 3.2 MB 3.2 MB 3.2 MB 3.3 MB
Download Download Download Download Download

Equipment

This might also interest you

Application examples

Rotary_evaporators
Rotary evaporators
Vacuum_concentrators
Vacuum concentrators
Oil-free_vacuum_for_reactors_and_synthesis_applications
Oil-free vacuum for reactors and synthesis applications

VARIO® chemistry pumping unit in action

The PC 3003 VARIO select pumping unit precisely controls the vacuum level in order to achieve unparalleled process control. With its high pumping speed and deep ultimate vacuum, this pump is suitable for demanding applications with high boiling point solvents in low temperature conditions. The integrated VACUU·SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run fully automated distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, the VACUU·SELECT controller continuously detects the boiling point and automatically adjusts the vacuum process as necessary. And the VARIO control algorithm maintains the desired vacuum level without running the motor faster than necessary. This prevents bumping and foaming, makes the pump whisper quiet, and extends maintenance intervals. The inlet separator, made of glass with a robust protective coating, prevents particles and liquid droplets from entering the pump, preventing damage and extending pump life. And the exhaust vapor condenser allows for nearly complete recovery of solvents when used with a chilled water line or recirculating chiller for economical recycling and environmental protection. Typical applications are all evaporation processes. They can be run fully automatically by the integrated vacuum controller CVC 3000 resulting in both shorter process times and extra sensitivity at the same time. The excellent ultimate vacuum allows even high boiling solvents to evaporate at low temperatures. The VARIO® control ensures high process reliability through prevention of superheating or foaming. It detects boiling pressures of solvents fully automatically and adapts continuously the vacuum conditions to changing process parameters. All this without any need of parameter input or the use of a solvent library. In many other applications - like in local vacuum networks - the VARIO® control offers a significant advantage by supplying always the appropriate pumping speed. The VACUU·BUS® interface facilitates an user-friendly configuration of even complex vacuum installations.


Information on the disposal of old devices »
 

Technical data and graphs

Max. pumping speed 50 Hz 2.8 m3/h Select diagram
Max. pumping speed 60 Hz 1.65 cfm
Ultimate vacuum 0.6 mbar / 0.45 torr
Ultimate vacuum with gas ballast 1.5 mbar / 1.12 torr
Number of heads 4
Number of stages 4
Vacuum controller VACUU·SELECT
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Max. outlet pressure (abs.) 1.1 bar
Inlet connection Hose nozzle DN 8-10 mm
Outlet connection Hose nozzle DN 8-10 mm
Coolant connection 2 x hose nozzle DN 6-8 mm
Rated motor power 0.53 kW
Protection class IEC 60529 IP 20
Dimension L in mm 419 mm
Dimension B in mm 243 mm
Dimension H in mm 457 mm
Weight 21.1 kg
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) 43 dBA
NRTL certification No
Items supplied Pumping unit completely mounted, ready for use, with manual.
Rated mains voltage range 1 100-120 V
Mains frequency 1 50-60 Hz
Interface Ethernet (RJ45): Modbus TCP / USB (Type A): Data transfer, software update, RS-232 (additional adapter required)

vac_pumpingspeedm3 für Zoom klicken

Max. pumping speed 50 Hz

vac_pumpingcurve50 für Zoom klicken

Pump down graph 50 Hz (10 l volume)

Downloads

VARIO chemistry pumping unit,PC 3003 VARIO select, 100-120V / 50-60Hz,US mains cable
PC 3003 VARIO select VARIO® chemistry pumping unit
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual vacuum gauge / controller
Manual PDF 17.5 MB 17.4 MB 17.4 MB 17.5 MB 17.4 MB 17.5 MB 17.4 MB 17.8 MB 17.5 MB 17.5 MB 17.4 MB 17.5 MB 17.5 MB 17.3 MB
Download Download Download Download Download Download Download Download Download Download Download Download Download Download
Manual interface
Manual PDF 1.8 MB 1.8 MB
Download Download
Manual vacuum pump
Manual PDF 15.3 MB 15.5 MB 15.3 MB 15.3 MB 15.2 MB 15.3 MB 15.3 MB 15.3 MB 15.3 MB 15.3 MB 15.3 MB 15.2 MB
Download Download Download Download Download Download Download Download Download Download Download Download
Manual function extension
Manual PDF 11.6 MB 11.4 MB
Download Download
Brochure
Brochure PDF 2 MB 2 MB
Download Download
Technical data sheet
Data sheet PDF 3.2 MB 3.2 MB 3.2 MB 3.2 MB 3.3 MB
Download Download Download Download Download

Equipment

This might also interest you

Application examples

Rotary_evaporators
Rotary evaporators
Vacuum_concentrators
Vacuum concentrators
Oil-free_vacuum_for_reactors_and_synthesis_applications
Oil-free vacuum for reactors and synthesis applications