MV 10C NTChemistry diaphragm pump

Overview

  • outstanding chemical resistance and superior vapor tolerance
  • reduced process time due to very high flow rates even close to ultimate vacuum
  • very low vibration and quiet
  • excellent ultimate vacuum even with gas ballast
  • excellent environmental friendliness due to efficient solvent recovery (on models with EK accessory)

Ultimate vacuum

0.9 mbar

Ultimate vacuum with gas ballast

1.5 mbar

Max. pumping speed 50 Hz

9.5 m3/h

On demand

Inquire

Chemistry diaphragm pump in action

Four-stage chemistry-design diaphragm pumps are an excellent solution for continuous, oil-free pumping of corrosive gases and vapors and meet highest requirements. The four-stage design of the eight-cylinder pump MV 10C NT provides the advantageous combination of high pumping speed and very low ultimate vacuum of 0.9 mbar in a very compact design. All internal parts in contact with pumped media are made of chemically resistant fluoroplastics. Well-proven PTFE sandwich diaphragms increase reliability and extend operating life. Upgraded with an exhaust waste vapor condenser (EK) the MV 10C NT +EK provides an excellent, environmentally friendly system with efficient solvent recovery. A separator for the inlet (AK) made of glass (with protective coating) against particles and liquid droplets is available as an optional accessory. The high pumping speed and excellent ultimate vacuum of the MV 10C NT reduce the process time significantly. The pump meets the high vacuum requirements, e.g., of parallel processes in vacuum networks. Further typical applications are vacuum ovens, large rotary evaporators, pilot plants and mini-plants as well as kilo laboratories. For rough operating conditions we recommend an inlet separator (AK) to protect the pump from particles and liquid droplets. The exhaust waste vapor condenser on the MV 10C NT +EK (also available as accessory) enables near-100-percent solvent recovery, efficient recycling and active protection of the environment.


Information on the disposal of old devices »
 

Technical data and graphs

Max. pumping speed 50 Hz 9.5 m3/h Select diagram
Max. pumping speed 60 Hz 5.6 cfm Select diagram
Ultimate vacuum 0.9 mbar / 0.68 torr
Ultimate vacuum with gas ballast 1.5 mbar / 1.1 torr
Number of heads 8
Number of stages 4
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Max. back pressure (abs.) 1.1 bar
Inlet connection small flange KF DN 25
Outlet connection Hose nozzle DN 15 mm
Rated motor power 0.53 kW
Rated motor speed at 50/60 Hz 1650 min-1
Protection class IEC 60529 IP 40
Dimension L in mm 533 mm
Dimension B in mm 260 mm
Dimension H in mm 359 mm
Weight 28.1 kg
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) 50 dBA
ATEX conformity II 3/- G Ex h IIC T3 Gc X Internal Atm. only
NRTL certification No
Items supplied Pump completely mounted, ready for use, with manual.
Rated mains voltage range 1 200-230 V
Mains frequency 1 50-60 Hz

vac_pumpingspeedm3 für Zoom klicken

Max. pumping speed 50 Hz

vac_pumpingspeedcfm für Zoom klicken

Max. pumping speed 60 Hz

vac_pumpingcurve50 für Zoom klicken

Pump down graph 50 Hz (100 l volume)

vac_pumpingcurve60 für Zoom klicken

Pump down graph 60 Hz (100 l volume)

Downloads

MV 10C NT Chemistry diaphragm pump
MV 10C NT Chemistry diaphragm pump
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual vacuum pump
Manual PDF 19.6 MB 19.5 MB 19.6 MB 21.6 MB 19.5 MB
Download Download Download Download Download
Brochure
Brochure PDF 2 MB 2 MB
Download Download

This might also interest you

Chemistry diaphragm pump in action

Four-stage chemistry-design diaphragm pumps are an excellent solution for continuous, oil-free pumping of corrosive gases and vapors and meet highest requirements. The four-stage design of the eight-cylinder pump MV 10C NT provides the advantageous combination of high pumping speed and very low ultimate vacuum of 0.9 mbar in a very compact design. All internal parts in contact with pumped media are made of chemically resistant fluoroplastics. Well-proven PTFE sandwich diaphragms increase reliability and extend operating life. Upgraded with an exhaust waste vapor condenser (EK) the MV 10C NT +EK provides an excellent, environmentally friendly system with efficient solvent recovery. A separator for the inlet (AK) made of glass (with protective coating) against particles and liquid droplets is available as an optional accessory. The high pumping speed and excellent ultimate vacuum of the MV 10C NT reduce the process time significantly. The pump meets the high vacuum requirements, e.g., of parallel processes in vacuum networks. Further typical applications are vacuum ovens, large rotary evaporators, pilot plants and mini-plants as well as kilo laboratories. For rough operating conditions we recommend an inlet separator (AK) to protect the pump from particles and liquid droplets. The exhaust waste vapor condenser on the MV 10C NT +EK (also available as accessory) enables near-100-percent solvent recovery, efficient recycling and active protection of the environment.


Information on the disposal of old devices »
 

Technical data and graphs

Max. pumping speed 50 Hz 9.5 m3/h Select diagram
Max. pumping speed 60 Hz 5.6 cfm Select diagram
Ultimate vacuum 0.9 mbar / 0.68 torr
Ultimate vacuum with gas ballast 1.5 mbar / 1.1 torr
Number of heads 8
Number of stages 4
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Max. back pressure (abs.) 1.1 bar
Inlet connection small flange KF DN 25
Outlet connection Hose nozzle DN 15 mm
Rated motor power 0.53 kW
Rated motor speed at 50/60 Hz 1650 min-1
Protection class IEC 60529 IP 40
Dimension L in mm 533 mm
Dimension B in mm 260 mm
Dimension H in mm 359 mm
Weight 28.1 kg
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) 50 dBA
ATEX conformity II 3/- G Ex h IIC T3 Gc X Internal Atm. only
NRTL certification No
Items supplied Pump completely mounted, ready for use, with manual.
Rated mains voltage range 1 200-230 V
Mains frequency 1 50-60 Hz

vac_pumpingspeedm3 für Zoom klicken

Max. pumping speed 50 Hz

vac_pumpingspeedcfm für Zoom klicken

Max. pumping speed 60 Hz

vac_pumpingcurve50 für Zoom klicken

Pump down graph 50 Hz (100 l volume)

vac_pumpingcurve60 für Zoom klicken

Pump down graph 60 Hz (100 l volume)

Downloads

MV 10C NT Chemistry diaphragm pump
MV 10C NT Chemistry diaphragm pump
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual vacuum pump
Manual PDF 19.6 MB 19.5 MB 19.6 MB 21.6 MB 19.5 MB
Download Download Download Download Download
Brochure
Brochure PDF 2 MB 2 MB
Download Download

This might also interest you