Air admittance valve VB M-B KF DN16 / G1/4 with hose nipple G1/4" - 6/10 mm, VACUU·BUS, certification (NRTL): C/US
The electromagnetic solenoid valve VB M-B with valve orifice diameter 2.4 mm and VACUU·BUS® control connection operates in conjunction with the vacuum controller CVC 3000 or the vacuum gauge DCP 3000. It is frequently used for remote-controlled systems like interlocking systems and inert gas flushing. The gas inlet has a tubing connection, e.g., for inert gas. Larger venting valves are available on request.Technical data and graphs
Flange connection | Small flange KF DN 16 or hose nozzle DN 6/10 mm | |
Operation | VACUU·BUS® | |
Leakage rate | 1 x 10-3 mbar l/s | |
Leakage rate of seat | 1 x 10-6 | |
Max. switching frequency | 50 pro Min. | |
Gas inlet connection | Tubing connection DN 8/6 mm | |
Fitting length between flanges | 45 mm |
Downloads
Air admittance valve VB M-B KF DN16 /G1/4 with hose nipple G1/4" - 6/10 mm,VACUU·BUS, certification (NRTL): C/US
VB M-B
Air admittance valve
This might also interest you
-
VM 25 Diaphragm valve
- Chemically resistant
- Hand-operated
- Leak rate 1 x 10-4 mbar l/s
VGL Gas inlet valve- Hand operated
- Fixed, permanent fitting
- Leak rate 1 x 10-9 min l/s
VK 16 Ball valve- For rough and fine vacuum range
- Leak rate 1 x 10-6 min l/s
VKW-B Cooling water valve- Mains plug VACUU·BUS®
- Nominal width 1.5 mm
VV-B 6C Solenoid-operated valves- High operating cycles
- Long term tightness
- Leak rate 1 x 10-2 mbar l/s
VE 16 WIG High vacuum bellow valve- Excellent gas tightness
- Minimum degassing
- Leak rate 1 x 10-9 mbar l/s
VS 25 Butterfly valve- High conductance
- Minimal degassing rate
- Leak rate 1 x 10-6 mbar l/s
Air admittance valve in action
Air admittance valve VB M-B KF DN16 / G1/4 with hose nipple G1/4" - 6/10 mm, VACUU·BUS, certification (NRTL): C/US
The electromagnetic solenoid valve VB M-B with valve orifice diameter 2.4 mm and VACUU·BUS® control connection operates in conjunction with the vacuum controller CVC 3000 or the vacuum gauge DCP 3000. It is frequently used for remote-controlled systems like interlocking systems and inert gas flushing. The gas inlet has a tubing connection, e.g., for inert gas. Larger venting valves are available on request.
Technical data and graphs
Flange connection Small flange KF DN 16 or hose nozzle DN 6/10 mm Operation VACUU·BUS® Leakage rate 1 x 10-3 mbar l/s Leakage rate of seat 1 x 10-6 Max. switching frequency 50 pro Min. Gas inlet connection Tubing connection DN 8/6 mm Fitting length between flanges 45 mm Downloads
Air admittance valve VB M-B KF DN16 /G1/4 with hose nipple G1/4" - 6/10 mm,VACUU·BUS, certification (NRTL): C/USVB M-B Air admittance valve