PC 3004 VARIO selectVARIO® chemistry pumping unit

Overview

  • VACUU·SELECT vacuum controller with graphical user interface and predefined applications simplifies work in the laboratory
  • automatic boiling point detection and adjustment of the vacuum for short process times
  • powerful vacuum pump meets high vacuum requirements for most high boiling solvents
  • extraordinary diaphragm life, therefore minimum operational and servicing costs
  • excellent environmental compatibility through low energy consumption and efficient solvent recovery

Ultimate vacuum

1.5 mbar

Ultimate vacuum with gas ballast

3 mbar

Max. pumping speed 50 Hz

4.6 m3/h

On demand

Inquire

VARIO® chemistry pumping unit in action

The PC 3004 VARIO select pumping unit precisely controls the vacuum level in order to achieve unparalleled process control. With its high pumping speed and deep ultimate vacuum, this pump is suitable for demanding applications with even high boiling point solvents. The integrated VACUU·SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run fully automated distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, the VACUU·SELECT controller continuously detects the boiling point and automatically adjusts the vacuum process as necessary. And the VARIO control algorithm maintains the desired vacuum level without running the motor faster than necessary. This prevents bumping and foaming, makes the pump whisper quiet, and extends maintenance intervals. The inlet separator, made of glass with a robust protective coating, prevents particles and liquid droplets from entering the pump, preventing damage and extending pump life. And the exhaust vapor condenser allows for nearly complete recovery of solvents when used with a chilled water line or recirculating chiller for economical recycling and environmental protection. Typical applications are all evaporation processes. They can be run fully automatically and with shorter process times and extra sensitivity even for challenging mixtures at the same time. The VARIO® control ensures high process reliability through prevention of boiling retardation or foaming. It detects boiling pressures automatically and self-adapts to changing process parameters at any time. This all without any need of parameter input or the use of a solvent library. Also in many other applications and in laboratory vacuum networks the VARIO® control brings significant advantages as it provides always the appropriate pumping speed. The VACUU·BUS® interface facilitates an user-friendly configuration of even complex vacuum installations.


Information on the disposal of old devices »
 

Technical data and graphs

Max. pumping speed 50 Hz 4.6 m3/h Select diagram
Max. pumping speed 60 Hz 2.7 cfm
Ultimate vacuum 1.5 mbar / 1.1 torr
Ultimate vacuum with gas ballast 3 mbar / 2.2 torr
Number of heads 4
Number of stages 3
Vacuum controller VACUU·SELECT
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Max. back pressure (abs.) 1.1 bar
Inlet connection Hose nozzle DN 8-10 mm
Outlet connection Hose nozzle DN 8-10 mm
Coolant connection 2 x hose nozzle DN 6-8 mm
Rated motor power 0.53 kW
Protection class IEC 60529 IP 20
Dimension L in mm 419 mm
Dimension B in mm 243 mm
Dimension H in mm 457 mm
Weight 21.1 kg
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) 43 dBA
NRTL certification No
Items supplied Pumping unit completely mounted, ready for use, with manual.
Rated mains voltage range 1 200-230 V
Mains frequency 1 50-60 Hz
Interface Ethernet (RJ45): Modbus TCP / USB (Type A): Data transfer, software update, RS-232 (additional adapter required)

vac_pumpingspeedm3 für Zoom klicken

Max. pumping speed 50 Hz

vac_pumpingcurve50 für Zoom klicken

Pump down graph 50 Hz (10 l volume)

Downloads

PC 3004 VARIO select VARIO® chemistry pumping unit
PC 3004 VARIO select VARIO® chemistry pumping unit
Manual vacuum gauge / controller
Manual PDF 17.4 MB 17.1 MB 17.5 MB 17.4 MB 17.4 MB 17.5 MB 17.4 MB 17.5 MB 17.4 MB 17.8 MB 17.5 MB 17.5 MB 17.4 MB 17.5 MB 17.5 MB 17.3 MB
Download Download Download Download Download Download Download Download Download Download Download Download Download Download Download Download
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual interface
Manual PDF 1.8 MB 1.8 MB
Download Download
Manual vacuum pump
Manual PDF 15.3 MB 15.5 MB 15.3 MB 15.7 MB 15.3 MB 15.2 MB 15.3 MB 15.3 MB 15.3 MB 15.3 MB 15.3 MB 15.3 MB 15.2 MB
Download Download Download Download Download Download Download Download Download Download Download Download Download
Manual function extension
Manual PDF 11.6 MB 11.4 MB
Download Download
Brochure
Brochure PDF 2 MB 2 MB
Download Download

Equipment

This might also interest you

Application examples

Rotary_evaporators
Rotary evaporators
Vacuum_concentrators
Vacuum concentrators
Oil-free_vacuum_for_reactors_and_synthesis_applications
Oil-free vacuum for reactors and synthesis applications
Vacuum_drying_oven
Vacuum drying oven

VARIO® chemistry pumping unit in action

The PC 3004 VARIO select pumping unit precisely controls the vacuum level in order to achieve unparalleled process control. With its high pumping speed and deep ultimate vacuum, this pump is suitable for demanding applications with even high boiling point solvents. The integrated VACUU·SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run fully automated distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, the VACUU·SELECT controller continuously detects the boiling point and automatically adjusts the vacuum process as necessary. And the VARIO control algorithm maintains the desired vacuum level without running the motor faster than necessary. This prevents bumping and foaming, makes the pump whisper quiet, and extends maintenance intervals. The inlet separator, made of glass with a robust protective coating, prevents particles and liquid droplets from entering the pump, preventing damage and extending pump life. And the exhaust vapor condenser allows for nearly complete recovery of solvents when used with a chilled water line or recirculating chiller for economical recycling and environmental protection. Typical applications are all evaporation processes. They can be run fully automatically and with shorter process times and extra sensitivity even for challenging mixtures at the same time. The VARIO® control ensures high process reliability through prevention of boiling retardation or foaming. It detects boiling pressures automatically and self-adapts to changing process parameters at any time. This all without any need of parameter input or the use of a solvent library. Also in many other applications and in laboratory vacuum networks the VARIO® control brings significant advantages as it provides always the appropriate pumping speed. The VACUU·BUS® interface facilitates an user-friendly configuration of even complex vacuum installations.


Information on the disposal of old devices »
 

Technical data and graphs

Max. pumping speed 50 Hz 4.6 m3/h Select diagram
Max. pumping speed 60 Hz 2.7 cfm
Ultimate vacuum 1.5 mbar / 1.1 torr
Ultimate vacuum with gas ballast 3 mbar / 2.2 torr
Number of heads 4
Number of stages 3
Vacuum controller VACUU·SELECT
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Max. back pressure (abs.) 1.1 bar
Inlet connection Hose nozzle DN 8-10 mm
Outlet connection Hose nozzle DN 8-10 mm
Coolant connection 2 x hose nozzle DN 6-8 mm
Rated motor power 0.53 kW
Protection class IEC 60529 IP 20
Dimension L in mm 419 mm
Dimension B in mm 243 mm
Dimension H in mm 457 mm
Weight 21.1 kg
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) 43 dBA
NRTL certification No
Items supplied Pumping unit completely mounted, ready for use, with manual.
Rated mains voltage range 1 200-230 V
Mains frequency 1 50-60 Hz
Interface Ethernet (RJ45): Modbus TCP / USB (Type A): Data transfer, software update, RS-232 (additional adapter required)

vac_pumpingspeedm3 für Zoom klicken

Max. pumping speed 50 Hz

vac_pumpingcurve50 für Zoom klicken

Pump down graph 50 Hz (10 l volume)

Downloads

PC 3004 VARIO select VARIO® chemistry pumping unit
PC 3004 VARIO select VARIO® chemistry pumping unit
Manual vacuum gauge / controller
Manual PDF 17.4 MB 17.1 MB 17.5 MB 17.4 MB 17.4 MB 17.5 MB 17.4 MB 17.5 MB 17.4 MB 17.8 MB 17.5 MB 17.5 MB 17.4 MB 17.5 MB 17.5 MB 17.3 MB
Download Download Download Download Download Download Download Download Download Download Download Download Download Download Download Download
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual interface
Manual PDF 1.8 MB 1.8 MB
Download Download
Manual vacuum pump
Manual PDF 15.3 MB 15.5 MB 15.3 MB 15.7 MB 15.3 MB 15.2 MB 15.3 MB 15.3 MB 15.3 MB 15.3 MB 15.3 MB 15.3 MB 15.2 MB
Download Download Download Download Download Download Download Download Download Download Download Download Download
Manual function extension
Manual PDF 11.6 MB 11.4 MB
Download Download
Brochure
Brochure PDF 2 MB 2 MB
Download Download

Equipment

This might also interest you

Application examples

Rotary_evaporators
Rotary evaporators
Vacuum_concentrators
Vacuum concentrators
Oil-free_vacuum_for_reactors_and_synthesis_applications
Oil-free vacuum for reactors and synthesis applications
Vacuum_drying_oven
Vacuum drying oven