MD 4C NT +2AKChemistry vacuum system

Overview

  • outstanding chemical resistance and superior vapor tolerance
  • exceptionally high performance even at low vacuum
  • excellent ultimate vacuum even with gas ballast
  • whisper quiet and very low vibration
  • separators at inlet and outlet to collect condensates

Ultimate vacuum

1.5 mbar

Ultimate vacuum with gas ballast

3 mbar

Max. pumping speed 50 Hz

3.4 m3/h

On demand

Inquire

Chemistry vacuum system in action

This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors in chemical, biological and pharmaceutical laboratories that do not require condensation of solvent vapors at the outlet. This system is well proven for high vacuum requirements with high boiling solvents. Typical applications are vacuum concentrators, rotary evaporators and drying ovens. The separator at the inlet (AK), made of glass with a protective coating, retains particles and liquid droplets. The catchpot at the outlet collects condensate, avoids condensate backflow towards the pump and reinforces the whisper-quiet operation of the pump.


Information on the disposal of old devices »
 

Technical data and graphs

Max. pumping speed 50 Hz 3.4 m3/h Select diagram
Max. pumping speed 60 Hz 2.2 cfm Select diagram
Ultimate vacuum 1.5 mbar / 1.1 torr
Ultimate vacuum with gas ballast 3 mbar / 2.2 torr
Number of heads 4
Number of stages 3
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Max. back pressure (abs.) 1.1 bar
Inlet connection Hose nozzle DN 8-10 mm
Outlet connection Hose nozzle DN 8-10 mm
Rated motor power 0.25 kW
Rated motor speed at 50/60 Hz 1500/1800 min-1
Protection class IEC 60529 IP 40
Dimension L in mm 319 mm
Dimension B in mm 243 mm
Dimension H in mm 374 mm
Weight 16.7 kg
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) 45 dBA
NRTL certification Yes
Items supplied Pumping unit completely mounted, ready for use, with manual.
Rated mains voltage range 1 230 V
Mains frequency 1 50-60 Hz

vac_pumpingspeedm3 für Zoom klicken

Max. pumping speed 50 Hz

vac_pumpingspeedcfm für Zoom klicken

Max. pumping speed 60 Hz

vac_pumpingcurve50 für Zoom klicken

Pump down graph 50 Hz (10 l volume)

vac_pumpingcurve60 für Zoom klicken

Pump down graph 60 Hz (10 l volume)

Downloads

MD 4C NT +2AK Chemistry vacuum system
MD 4C NT +2AK Chemistry vacuum system
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual vacuum pump
Manual PDF 4.3 MB 4.3 MB 4.3 MB 4.3 MB 4.2 MB 4.3 MB 4.3 MB 4.3 MB 4.3 MB 4.3 MB 4.4 MB 4.8 MB 4.3 MB 4.2 MB 4.3 MB
Download Download Download Download Download Download Download Download Download Download Download Download Download Download Download
Brochure
Brochure PDF 2 MB 2 MB
Download Download

This might also interest you

Chemistry vacuum system in action

This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors in chemical, biological and pharmaceutical laboratories that do not require condensation of solvent vapors at the outlet. This system is well proven for high vacuum requirements with high boiling solvents. Typical applications are vacuum concentrators, rotary evaporators and drying ovens. The separator at the inlet (AK), made of glass with a protective coating, retains particles and liquid droplets. The catchpot at the outlet collects condensate, avoids condensate backflow towards the pump and reinforces the whisper-quiet operation of the pump.


Information on the disposal of old devices »
 

Technical data and graphs

Max. pumping speed 50 Hz 3.4 m3/h Select diagram
Max. pumping speed 60 Hz 2.2 cfm Select diagram
Ultimate vacuum 1.5 mbar / 1.1 torr
Ultimate vacuum with gas ballast 3 mbar / 2.2 torr
Number of heads 4
Number of stages 3
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Max. back pressure (abs.) 1.1 bar
Inlet connection Hose nozzle DN 8-10 mm
Outlet connection Hose nozzle DN 8-10 mm
Rated motor power 0.25 kW
Rated motor speed at 50/60 Hz 1500/1800 min-1
Protection class IEC 60529 IP 40
Dimension L in mm 319 mm
Dimension B in mm 243 mm
Dimension H in mm 374 mm
Weight 16.7 kg
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) 45 dBA
NRTL certification Yes
Items supplied Pumping unit completely mounted, ready for use, with manual.
Rated mains voltage range 1 230 V
Mains frequency 1 50-60 Hz

vac_pumpingspeedm3 für Zoom klicken

Max. pumping speed 50 Hz

vac_pumpingspeedcfm für Zoom klicken

Max. pumping speed 60 Hz

vac_pumpingcurve50 für Zoom klicken

Pump down graph 50 Hz (10 l volume)

vac_pumpingcurve60 für Zoom klicken

Pump down graph 60 Hz (10 l volume)

Downloads

MD 4C NT +2AK Chemistry vacuum system
MD 4C NT +2AK Chemistry vacuum system
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual vacuum pump
Manual PDF 4.3 MB 4.3 MB 4.3 MB 4.3 MB 4.2 MB 4.3 MB 4.3 MB 4.3 MB 4.3 MB 4.3 MB 4.4 MB 4.8 MB 4.3 MB 4.2 MB 4.3 MB
Download Download Download Download Download Download Download Download Download Download Download Download Download Download Download
Brochure
Brochure PDF 2 MB 2 MB
Download Download

This might also interest you