CVC 3000 + VACUU·VIEW extended, KF DN 16Package fine vacuum control

Overview

  • the CVC 3000 controls vacuum, cooling water and venting to demand
  • intuitive operation with turn-and-tap jog wheel and clear text menus
  • rugged VACUU·VIEW extended vacuum gauge with high chemical resistance and mechanical robustness
  • VACUU·VIEW extended with wide measurement range from atmospheric pressure to fine vacuum (10-3 mbar)
  • the in-line solenoid valve is chemically highly resistant (series C)
Articleno. 20683201
On demand

Inquire

Package fine vacuum control in action

The packages enable convenient vacuum control in the fine vacuum range down to 10-3 mbar and consist of a CVC 3000 vacuum controller, a VACUU·VIEW extended vacuum gauge, a VV-B 15C in-line solenoid valve and all necessary small flange components. VACUUBRAND offers two packages, one with small flanges KF DN 16, suitable, e.g., for the VACUUBRAND RE/RZ 2.5 to RE/RZ 6 rotary vane pumps or our RC 6 Chemistry-HYBRID pump; or select the small flange KF DN 25 version suitable for our RE/RZ 9 rotary vane pumps. The CVC 3000 runs vacuum processes by control of external vacuum, venting and cooling water valves. In these packages the vacuum control is performed by opening and closing the in-line solenoid valve VV-B 15C. The controller and components are completely self-configuring and automatically checked via VACUU·BUS® communication protocol. ###


Information on the disposal of old devices »

Technical data and graphs

Upper measuring limit in mbar/hPa 1100 mbar
Upper measuring limit in torr 825 torr
Lower measuring limit in mbar/hPa 1 x 10-3
Lower measuring limit in torr 1 x 10-3 torr
Measurement principle Ceramic diaphragm sensor + ceramic jacketed Pirani sensor
Accuracy of measurement +- 15% of indicated value in the range 0.01-5 mbar / +-3 mbar for > 5 mbar mbar/hPa/torr
Vacuum sensor VACUU·VIEW extended
Temperature coefficient +- 0.2 mbar/hPa/0.15 torr /K mbar/hPa/torr /K
Vacum connection Small flange KF DN 16 / hose nozzle DN 10 mm
Venting valve No
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 20
Protection class UL50E Type 1
Protection class front side IEC 60529 IP 42
Dimension L in mm 144 mm
Dimension B in mm 124 mm
Dimension H in mm 115 mm
Weight 0.44 kg
Max. current for VACUU BUS (24V DC) 4 A
Cable length connection in m 2 m
Interface RS 232C
NRTL certification Yes
Items supplied Package for fine vacuum control, consisting of: Vacuum controller CVC 3000 (without internal vacuum sensor and venting valve) with VACUU·VIEW extended and power supply, in-line solenoid valve VV-B 15C KF DN 16, T-piece KF DN 16, hose nozzle DN 10 mm (PP), clamping and sealing rings, ready for use, with manual.

Downloads

CVC 3000 + VACUU·VIEW extended, KF DN 16 Package fine vacuum control
Manual vacuum gauge / controller
Manual PDF 17.6 MB 18.8 MB 18.3 MB
Download Download Download

Equipment

This might also interest you

Package fine vacuum control in action

The packages enable convenient vacuum control in the fine vacuum range down to 10-3 mbar and consist of a CVC 3000 vacuum controller, a VACUU·VIEW extended vacuum gauge, a VV-B 15C in-line solenoid valve and all necessary small flange components. VACUUBRAND offers two packages, one with small flanges KF DN 16, suitable, e.g., for the VACUUBRAND RE/RZ 2.5 to RE/RZ 6 rotary vane pumps or our RC 6 Chemistry-HYBRID pump; or select the small flange KF DN 25 version suitable for our RE/RZ 9 rotary vane pumps. The CVC 3000 runs vacuum processes by control of external vacuum, venting and cooling water valves. In these packages the vacuum control is performed by opening and closing the in-line solenoid valve VV-B 15C. The controller and components are completely self-configuring and automatically checked via VACUU·BUS® communication protocol. ###


Information on the disposal of old devices »

Technical data and graphs

Upper measuring limit in mbar/hPa 1100 mbar
Upper measuring limit in torr 825 torr
Lower measuring limit in mbar/hPa 1 x 10-3
Lower measuring limit in torr 1 x 10-3 torr
Measurement principle Ceramic diaphragm sensor + ceramic jacketed Pirani sensor
Accuracy of measurement +- 15% of indicated value in the range 0.01-5 mbar / +-3 mbar for > 5 mbar mbar/hPa/torr
Vacuum sensor VACUU·VIEW extended
Temperature coefficient +- 0.2 mbar/hPa/0.15 torr /K mbar/hPa/torr /K
Vacum connection Small flange KF DN 16 / hose nozzle DN 10 mm
Venting valve No
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 20
Protection class UL50E Type 1
Protection class front side IEC 60529 IP 42
Dimension L in mm 144 mm
Dimension B in mm 124 mm
Dimension H in mm 115 mm
Weight 0.44 kg
Max. current for VACUU BUS (24V DC) 4 A
Cable length connection in m 2 m
Interface RS 232C
NRTL certification Yes
Items supplied Package for fine vacuum control, consisting of: Vacuum controller CVC 3000 (without internal vacuum sensor and venting valve) with VACUU·VIEW extended and power supply, in-line solenoid valve VV-B 15C KF DN 16, T-piece KF DN 16, hose nozzle DN 10 mm (PP), clamping and sealing rings, ready for use, with manual.