PC 620 selectChemistry pumping unit

Overview

  • VACUU·SELECT vacuum controller with graphical user interface simplifies work in the laboratory
  • predefined applications save time and give reproducible result
  • easy-to-use application editor allows own process sequences
  • meets high vacuum requirements for most high boiling solvents
  • PC 620 select allows simultaneous operation of two independent vacuum applications with electronic vacuum control

Ultimate vacuum

1.5 mbar

Ultimate vacuum with gas ballast

3 mbar

Max. pumping speed 50 Hz

3.4 m3/h

Articleno. 20737357
On demand

Inquire

Chemistry pumping unit in action

This chemistry vacuum pumping unit is an economical, compact solution for simultaneous operation of two electronically controlled vacuum applications with a single pump. Based on our popular MD 4C NT three-stage chemistry diaphragm pump, the PC 620 select is frequently used for vacuum applications involving even high boiling point solvents. This pump has sufficient capacity to run two demanding applications simultaneously. Both vacuum ports have independent solenoid valves for electronic vacuum control, and check valves to protect against cross contamination and interference. The integrated VACUU·SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, it constantly monitors the pressure and switches to 2 point control mode to hold the pressure stable when a boiling point is detected. The inlet separator, made of glass with a robust protective coating, prevents particles and liquid droplets from entering the pump, preventing damage and extending pump life. And the exhaust vapor condenser allows for nearly complete recovery of solvents when used with a chilled water line or recirculating chiller for economical recycling and environmental protection.


Information on the disposal of old devices »
 

Technical data and graphs

Max. pumping speed 50 Hz 3.4 m3/h Select diagram
Max. pumping speed 60 Hz 2.2 cfm Select diagram
Ultimate vacuum 1.5 mbar / 1.1 torr
Ultimate vacuum with gas ballast 3 mbar / 2.2 torr
Number of heads 4
Number of stages 3
Vacuum controller VACUU·SELECT
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Max. back pressure (abs.) 1.1 bar
Inlet connection 2 x hose nozzle DN 8-10 mm
Outlet connection Hose nozzle DN 8-10 mm
Coolant connection 2 x hose nozzle DN 6-8 mm
Rated motor power 0.25 kW
Rated motor speed at 50/60 Hz 1500/1800 min-1
Protection class IEC 60529 IP 20
Dimension L in mm 435 mm
Dimension B in mm 243 mm
Dimension H in mm 457 mm
Weight 20.6 kg
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) 45 dBA
ATEX conformity II 3/- G Ex h IIC T3 Gc X Internal Atm. only
NRTL certification No
Items supplied Pumping unit completely mounted, ready for use, with manual.
Rated mains voltage range 1 230 V
Mains frequency 1 50-60 Hz
Interface Ethernet (RJ45): Modbus TCP / USB (Type A): Data transfer, software update, RS-232 (additional adapter required)

vac_pumpingspeedm3 für Zoom klicken

Max. pumping speed 50 Hz

vac_pumpingspeedcfm für Zoom klicken

Max. pumping speed 60 Hz

vac_pumpingcurve50 für Zoom klicken

Pump down graph 50 Hz (10 l volume)

vac_pumpingcurve60 für Zoom klicken

Pump down graph 60 Hz (10 l volume)

Downloads

Chemistry pumping unit PC 620 select, with MD 4C NT,230V / 50-60Hz, IN mains cable
PC 620 select Chemistry pumping unit
Manual vacuum gauge / controller
Manual PDF 17.4 MB 17.1 MB 17.5 MB 17.4 MB 17.4 MB 17.5 MB 17.4 MB 17.5 MB 17.4 MB 17.8 MB 17.5 MB 17.5 MB 17.4 MB 17.5 MB 17.5 MB 17.3 MB
Download Download Download Download Download Download Download Download Download Download Download Download Download Download Download Download
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual interface
Manual PDF 1.8 MB 1.8 MB
Download Download
Manual vacuum pump
Manual PDF 16 MB 16.1 MB 16.1 MB 16.1 MB 16.1 MB 16.1 MB 16.1 MB 16.1 MB 14.9 MB 17.2 MB 16 MB 16 MB 16.6 MB
Download Download Download Download Download Download Download Download Download Download Download Download Download
Manual function extension
Manual PDF 11.6 MB 11.4 MB
Download Download
Brochure
Brochure PDF 2 MB 2 MB
Download Download
Technical data sheet
Data sheet PDF 3.7 MB 3.7 MB 3.7 MB 3.7 MB 3.7 MB
Download Download Download Download Download

This might also interest you

Application examples

Rotary_evaporators
Rotary evaporators

Chemistry pumping unit in action

This chemistry vacuum pumping unit is an economical, compact solution for simultaneous operation of two electronically controlled vacuum applications with a single pump. Based on our popular MD 4C NT three-stage chemistry diaphragm pump, the PC 620 select is frequently used for vacuum applications involving even high boiling point solvents. This pump has sufficient capacity to run two demanding applications simultaneously. Both vacuum ports have independent solenoid valves for electronic vacuum control, and check valves to protect against cross contamination and interference. The integrated VACUU·SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, it constantly monitors the pressure and switches to 2 point control mode to hold the pressure stable when a boiling point is detected. The inlet separator, made of glass with a robust protective coating, prevents particles and liquid droplets from entering the pump, preventing damage and extending pump life. And the exhaust vapor condenser allows for nearly complete recovery of solvents when used with a chilled water line or recirculating chiller for economical recycling and environmental protection.


Information on the disposal of old devices »
 

Technical data and graphs

Max. pumping speed 50 Hz 3.4 m3/h Select diagram
Max. pumping speed 60 Hz 2.2 cfm Select diagram
Ultimate vacuum 1.5 mbar / 1.1 torr
Ultimate vacuum with gas ballast 3 mbar / 2.2 torr
Number of heads 4
Number of stages 3
Vacuum controller VACUU·SELECT
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Max. back pressure (abs.) 1.1 bar
Inlet connection 2 x hose nozzle DN 8-10 mm
Outlet connection Hose nozzle DN 8-10 mm
Coolant connection 2 x hose nozzle DN 6-8 mm
Rated motor power 0.25 kW
Rated motor speed at 50/60 Hz 1500/1800 min-1
Protection class IEC 60529 IP 20
Dimension L in mm 435 mm
Dimension B in mm 243 mm
Dimension H in mm 457 mm
Weight 20.6 kg
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) 45 dBA
ATEX conformity II 3/- G Ex h IIC T3 Gc X Internal Atm. only
NRTL certification No
Items supplied Pumping unit completely mounted, ready for use, with manual.
Rated mains voltage range 1 230 V
Mains frequency 1 50-60 Hz
Interface Ethernet (RJ45): Modbus TCP / USB (Type A): Data transfer, software update, RS-232 (additional adapter required)

vac_pumpingspeedm3 für Zoom klicken

Max. pumping speed 50 Hz

vac_pumpingspeedcfm für Zoom klicken

Max. pumping speed 60 Hz

vac_pumpingcurve50 für Zoom klicken

Pump down graph 50 Hz (10 l volume)

vac_pumpingcurve60 für Zoom klicken

Pump down graph 60 Hz (10 l volume)

Downloads

Chemistry pumping unit PC 620 select, with MD 4C NT,230V / 50-60Hz, IN mains cable
PC 620 select Chemistry pumping unit
Manual vacuum gauge / controller
Manual PDF 17.4 MB 17.1 MB 17.5 MB 17.4 MB 17.4 MB 17.5 MB 17.4 MB 17.5 MB 17.4 MB 17.8 MB 17.5 MB 17.5 MB 17.4 MB 17.5 MB 17.5 MB 17.3 MB
Download Download Download Download Download Download Download Download Download Download Download Download Download Download Download Download
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual interface
Manual PDF 1.8 MB 1.8 MB
Download Download
Manual vacuum pump
Manual PDF 16 MB 16.1 MB 16.1 MB 16.1 MB 16.1 MB 16.1 MB 16.1 MB 16.1 MB 14.9 MB 17.2 MB 16 MB 16 MB 16.6 MB
Download Download Download Download Download Download Download Download Download Download Download Download Download
Manual function extension
Manual PDF 11.6 MB 11.4 MB
Download Download
Brochure
Brochure PDF 2 MB 2 MB
Download Download
Technical data sheet
Data sheet PDF 3.7 MB 3.7 MB 3.7 MB 3.7 MB 3.7 MB
Download Download Download Download Download

This might also interest you

Application examples

Rotary_evaporators
Rotary evaporators