VACUU·SELECT + VSP 3000, KF DN 16Package fine vacuum control

Overview

  • Complete package for vacuum control of all fine vacuum applications in chemical labs, with continuous control range from 5 mbar to fine vacuum (10-3 mbar)
  • graphic user interface for simple operation
  • predefined applications for quick, reproducible results
  • application editor allows easy customization
  • proprietary Pirani-type fine vacuum gauge offers superior chemical resistance and mechanical robustness
Articleno. 20700101
On demand

Inquire

Package fine vacuum control in action

The VACUU·SELECT fine vacuum control packages provide an easy-to-use vacuum control option for work down to 10-3 mbar. These packages include the VACUU·SELECT controller with fine vacuum gauge, a chemical-resistant inline isolation valve (VV-B 15C), and the accessories required for connection to your vacuum system via small flange (KF) connections. VACUUBRAND offers fine vacuum control packages with two different small flange connections. The KF DN 16 fine vacuum control package is compatible with our rotary vane pump models RE / RZ 2.5 to RE / RZ 6 and our HYBRID pump RC 6. The KF DN 25 fine vacuum control package is configured for use with our RE / RZ 9 rotary vane pumps and VACUU·PURE screw pumps. With its intuitive, application-based user interface, the controller allows you to quickly get your fine vacuum process under control. For advanced processes, pre-defined applications can be modified, and new applications can be created to optimize your process conditions. The included inline solenoid valve and sensor are automatically configured via the proprietary VACUU·BUS system.


Information on the disposal of old devices »

Technical data and graphs

Upper measuring limit in mbar/hPa 1000 mbar
Upper measuring limit in torr 750 torr
Lower measuring limit in mbar/hPa 1 x 10-3
Lower measuring limit in torr 1 x 10-3 torr
Measurement principle Thermal conductivity (Pirani), chemically resistant plastics / ceramics
Accuracy of measurement +- 15% of indicated value in the range 0.01-5 mbar/hPa/torr mbar/hPa/torr
Vacuum sensor VSP 3000
Temperature coefficient +- 0.2 mbar/hPa/0.15 torr /K mbar/hPa/torr /K
Vacum connection Small flange KF DN 16 / hose nozzle DN 10 mm
Venting valve No
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 40
Protection class UL50E Type 1
Protection class front side IEC 60529 IP 41
Protection class UL50E front side Type 2
Dimension L in mm 152 mm
Dimension B in mm 127 mm
Dimension H in mm 41 mm
Weight 0.6 kg
Max. current for VACUU BUS (24V DC) 4 A
Cable length connection in m 2 m
Interface Ethernet (RJ45): Modbus TCP / USB (Type A): Data transfer, software update, RS-232 (additional adapter required)
NRTL certification Yes
Items supplied Package for fine vacuum control, consisting of: Vacuum controller VACUU-SELECT (without internal vacuum sensor and venting valve) with VSP 3000 and power supply, solenoid valve VV-B 15C KF DN 16, T-piece KF DN 16, hose nozzle DN 10 mm (PP), clamping and sealing rings, ready for use, with manual.

Downloads

VACUU·SELECT package for fine vacuum controlwith Pirani sensor for KF DN 16, with in-lineisolation, valve VV-B 15C, T-piece,hose nozzle DN 10 and connecting parts DN 16,100-230V / 50-60Hz, plug CEE/CH/UK/US/AUS/CN
VACUU·SELECT + VSP 3000, KF DN 16 Package fine vacuum control
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual assembly
Manual PDF 1.1 MB
Multilingual Download
Manual vacuum gauge / controller
Manual PDF 17.5 MB 17.4 MB 17.4 MB 17.5 MB 17.4 MB 17.5 MB 1.1 MB 17.4 MB 17.8 MB 17.5 MB 17.5 MB 17.4 MB 17.5 MB 17.5 MB 17.3 MB
Download Download Download Download Download Download Download Download Download Download Download Download Download Download Download
Manual interface
Manual PDF 1.8 MB 1.8 MB
Download Download
Manual function extension
Manual PDF 11.6 MB 11.4 MB
Download Download

Equipment

This might also interest you

Package fine vacuum control in action

The VACUU·SELECT fine vacuum control packages provide an easy-to-use vacuum control option for work down to 10-3 mbar. These packages include the VACUU·SELECT controller with fine vacuum gauge, a chemical-resistant inline isolation valve (VV-B 15C), and the accessories required for connection to your vacuum system via small flange (KF) connections. VACUUBRAND offers fine vacuum control packages with two different small flange connections. The KF DN 16 fine vacuum control package is compatible with our rotary vane pump models RE / RZ 2.5 to RE / RZ 6 and our HYBRID pump RC 6. The KF DN 25 fine vacuum control package is configured for use with our RE / RZ 9 rotary vane pumps and VACUU·PURE screw pumps. With its intuitive, application-based user interface, the controller allows you to quickly get your fine vacuum process under control. For advanced processes, pre-defined applications can be modified, and new applications can be created to optimize your process conditions. The included inline solenoid valve and sensor are automatically configured via the proprietary VACUU·BUS system.


Information on the disposal of old devices »

Technical data and graphs

Upper measuring limit in mbar/hPa 1000 mbar
Upper measuring limit in torr 750 torr
Lower measuring limit in mbar/hPa 1 x 10-3
Lower measuring limit in torr 1 x 10-3 torr
Measurement principle Thermal conductivity (Pirani), chemically resistant plastics / ceramics
Accuracy of measurement +- 15% of indicated value in the range 0.01-5 mbar/hPa/torr mbar/hPa/torr
Vacuum sensor VSP 3000
Temperature coefficient +- 0.2 mbar/hPa/0.15 torr /K mbar/hPa/torr /K
Vacum connection Small flange KF DN 16 / hose nozzle DN 10 mm
Venting valve No
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 40
Protection class UL50E Type 1
Protection class front side IEC 60529 IP 41
Protection class UL50E front side Type 2
Dimension L in mm 152 mm
Dimension B in mm 127 mm
Dimension H in mm 41 mm
Weight 0.6 kg
Max. current for VACUU BUS (24V DC) 4 A
Cable length connection in m 2 m
Interface Ethernet (RJ45): Modbus TCP / USB (Type A): Data transfer, software update, RS-232 (additional adapter required)
NRTL certification Yes
Items supplied Package for fine vacuum control, consisting of: Vacuum controller VACUU-SELECT (without internal vacuum sensor and venting valve) with VSP 3000 and power supply, solenoid valve VV-B 15C KF DN 16, T-piece KF DN 16, hose nozzle DN 10 mm (PP), clamping and sealing rings, ready for use, with manual.

Downloads

VACUU·SELECT package for fine vacuum controlwith Pirani sensor for KF DN 16, with in-lineisolation, valve VV-B 15C, T-piece,hose nozzle DN 10 and connecting parts DN 16,100-230V / 50-60Hz, plug CEE/CH/UK/US/AUS/CN
VACUU·SELECT + VSP 3000, KF DN 16 Package fine vacuum control
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual assembly
Manual PDF 1.1 MB
Multilingual Download
Manual vacuum gauge / controller
Manual PDF 17.5 MB 17.4 MB 17.4 MB 17.5 MB 17.4 MB 17.5 MB 1.1 MB 17.4 MB 17.8 MB 17.5 MB 17.5 MB 17.4 MB 17.5 MB 17.5 MB 17.3 MB
Download Download Download Download Download Download Download Download Download Download Download Download Download Download Download
Manual interface
Manual PDF 1.8 MB 1.8 MB
Download Download
Manual function extension
Manual PDF 11.6 MB 11.4 MB
Download Download

Equipment

This might also interest you