VACUU·BUS®Digital-I/O-Module VACUU·BUS®

Overview

  • digital input of control signals via a galvanically isolated input
  • digital output of status signals via a potential-free semiconductor relay
  • fault indicator from and to the vacuum controller
  • configurable as remote (Start/Stop) module
  • configurable as process-stop module with optional function for opening a relay or valve at process end
Articleno. 20636228
On demand

Inquire

Digital-I/O-Module VACUU·BUS® in action

Digital I/O interface module VACUU·BUS, with 2 m VACUU·BUS cable

The Digital-I/O-Module is a digital interface for VACUU·BUS® compatible vacuum gauges and controllers. There is a galvanically isolated input gate and a potential-free semiconductor relay for output switching. By default the Digital-I/O-Module is configured as bidirectional fault indicator module to communicate malfunctions in a vacuum system to the process control system, or in case of external malfunction to interrupt the process. When configured as Start/Stop module a process can be started and stopped from a PLC. In addition the Digital-I/O-Module can be configured for control of valves not compatible with VACUU·BUS®. In combination with the vacuum gauge DCP 3000 set points can be defined for the control of, e.g., high vacuum pumping units, load locks, etc.


More Information
Promotion Label Select -18%

Technical data and graphs

Items supplied Digital-I/O-Module VACUU·BUS® complete with cable VACUU·BUS® 2m.

Downloads

Digital I/O interface module VACUU·BUS,with 2 m VACUU·BUS cable
VACUU·BUS®
Digital-I/O-Module VACUU·BUS®
Manual accessories
Manual PDF 7.1 MB 6.5 MB 7.4 MB
Download Download Download

Digital-I/O-Module VACUU·BUS® in action

Digital I/O interface module VACUU·BUS, with 2 m VACUU·BUS cable

The Digital-I/O-Module is a digital interface for VACUU·BUS® compatible vacuum gauges and controllers. There is a galvanically isolated input gate and a potential-free semiconductor relay for output switching. By default the Digital-I/O-Module is configured as bidirectional fault indicator module to communicate malfunctions in a vacuum system to the process control system, or in case of external malfunction to interrupt the process. When configured as Start/Stop module a process can be started and stopped from a PLC. In addition the Digital-I/O-Module can be configured for control of valves not compatible with VACUU·BUS®. In combination with the vacuum gauge DCP 3000 set points can be defined for the control of, e.g., high vacuum pumping units, load locks, etc.


More Information
Promotion Label Select -18%

Technical data and graphs

Items supplied Digital-I/O-Module VACUU·BUS® complete with cable VACUU·BUS® 2m.