ME 2C NTChemistry diaphragm pump

Overview

  • whisper quiet and very low vibration
  • powerful, even for parallel operation of several applications
  • high performance even at low vacuum levels
  • outstanding chemical resistance
  • long diaphragm life, maintenance-free drive system

Ultimate vacuum

70 mbar

Max. pumping speed 50 Hz

2.1 m3/h

Articleno. 20730100
On demand

Inquire

Chemistry diaphragm pump in action

One-stage diaphragm pumps are an excellent solution for continuous, oil-free pumping of gases and vapors at low vacuum requirement. In contrast to waterjet pumps they do not consume water and therefore do not produce any contaminated waste water in daily use. Typical applications are vacuum ovens, filtrations and multi-port manifolds for medium throughput, as well as pumping of gases and oil-free evacuation in general. The one-stage construction provides the advantageous combination of high pumping speed and low ultimate vacuum down to 70 mbar. One-stage chemistry diaphragm vacuum pumps are an excellent choice for applications with corrosive gases and vapors which do not require very deep vacuum levels. Typical applications are vacuum ovens, filtrations as well as concentration of solvents with low boiling points. All major parts in contact with pumped media are made of chemically resistant fluoroplastics. The well proven robust PTFE sandwich diaphragm provides outstanding reliability and operating life.


Information on the disposal of old devices »
 

Technical data and graphs

Max. pumping speed 50 Hz 2.1 m3/h Select diagram
Max. pumping speed 60 Hz 1.4 cfm Select diagram
Ultimate vacuum 70 mbar / 52 torr
Number of heads 1
Number of stages 1
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Max. back pressure (abs.) 1.1 bar
Inlet connection Hose nozzle DN 8-10 mm
Outlet connection Hose nozzle DN 8-10 mm
Rated motor power 0.18 kW
Rated motor speed at 50/60 Hz 1500/1800 min-1
Protection class IEC 60529 IP 40
Dimension L in mm 243 mm
Dimension B in mm 211 mm
Dimension H in mm 198 mm
Weight 10.2 kg
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) 45 dBA
ATEX conformity II 3/- G Ex h IIC T3 Gc X Internal Atm. only
NRTL certification Yes
Items supplied Pump completely mounted, ready for use, with manual.
Rated mains voltage range 1 230 V
Mains frequency 1 50-60 Hz

vac_pumpingspeedm3 für Zoom klicken

Max. pumping speed 50 Hz

vac_pumpingspeedcfm für Zoom klicken

Max. pumping speed 60 Hz

vac_pumpingcurve50 für Zoom klicken

Pump down graph 50 Hz (10 l volume)

vac_pumpingcurve60 für Zoom klicken

Pump down graph 60 Hz (10 l volume)

Downloads

Chemistry diaphragm pump ME 2C NT,one stage, certification (NRTL): C/US230 V / 50-60 Hz, CEE mains cable
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual vacuum pump
Manual PDF 4.2 MB 4.3 MB 4.3 MB 4.3 MB 4.4 MB 4.8 MB
Download Download Download Download Download Download
Chemistry diaphragm pump ME 2C NT,one stage, certification (NRTL): C/US230 V / 50-60 Hz, CEE mains cable
Brochure PDF 2 MB 2 MB
Download Download

This might also interest you

Application examples

Filtration_and_solid_phase_extraction
Filtration and solid phase extraction

Chemistry diaphragm pump in action

One-stage diaphragm pumps are an excellent solution for continuous, oil-free pumping of gases and vapors at low vacuum requirement. In contrast to waterjet pumps they do not consume water and therefore do not produce any contaminated waste water in daily use. Typical applications are vacuum ovens, filtrations and multi-port manifolds for medium throughput, as well as pumping of gases and oil-free evacuation in general. The one-stage construction provides the advantageous combination of high pumping speed and low ultimate vacuum down to 70 mbar. One-stage chemistry diaphragm vacuum pumps are an excellent choice for applications with corrosive gases and vapors which do not require very deep vacuum levels. Typical applications are vacuum ovens, filtrations as well as concentration of solvents with low boiling points. All major parts in contact with pumped media are made of chemically resistant fluoroplastics. The well proven robust PTFE sandwich diaphragm provides outstanding reliability and operating life.


Information on the disposal of old devices »
 

Technical data and graphs

Max. pumping speed 50 Hz 2.1 m3/h Select diagram
Max. pumping speed 60 Hz 1.4 cfm Select diagram
Ultimate vacuum 70 mbar / 52 torr
Number of heads 1
Number of stages 1
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Max. back pressure (abs.) 1.1 bar
Inlet connection Hose nozzle DN 8-10 mm
Outlet connection Hose nozzle DN 8-10 mm
Rated motor power 0.18 kW
Rated motor speed at 50/60 Hz 1500/1800 min-1
Protection class IEC 60529 IP 40
Dimension L in mm 243 mm
Dimension B in mm 211 mm
Dimension H in mm 198 mm
Weight 10.2 kg
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) 45 dBA
ATEX conformity II 3/- G Ex h IIC T3 Gc X Internal Atm. only
NRTL certification Yes
Items supplied Pump completely mounted, ready for use, with manual.
Rated mains voltage range 1 230 V
Mains frequency 1 50-60 Hz

vac_pumpingspeedm3 für Zoom klicken

Max. pumping speed 50 Hz

vac_pumpingspeedcfm für Zoom klicken

Max. pumping speed 60 Hz

vac_pumpingcurve50 für Zoom klicken

Pump down graph 50 Hz (10 l volume)

vac_pumpingcurve60 für Zoom klicken

Pump down graph 60 Hz (10 l volume)

Downloads

Chemistry diaphragm pump ME 2C NT,one stage, certification (NRTL): C/US230 V / 50-60 Hz, CEE mains cable
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual vacuum pump
Manual PDF 4.2 MB 4.3 MB 4.3 MB 4.3 MB 4.4 MB 4.8 MB
Download Download Download Download Download Download
Chemistry diaphragm pump ME 2C NT,one stage, certification (NRTL): C/US230 V / 50-60 Hz, CEE mains cable
Brochure PDF 2 MB 2 MB
Download Download

This might also interest you

Application examples

Filtration_and_solid_phase_extraction
Filtration and solid phase extraction