VACUU·BUS®Analog-I/O-Module 0-10V VACUU·BUS®

Overview

  • analog output of the vacuum measurment as a 0-10 V signal
  • analog setting of the target vacuum as a 0-10 V signal
  • configurable for the input and output of set and/or actual values of the motor speed with VARIO® pumps or VARIO® pumping units
  • resolution of the analog output signal is 2.5 mV
  • color LED status indication
Articleno. 20636229
On demand
VACUU·BUS® Analog-I/O-Module 0-10V VACUU·BUS®

By submitting the contact form, you agree that your data will be used to process your request. If your inquiry comes from a country in which we do not have our own sales department, you also consent to your data being forwarded to the responsible local trading partner. You can find an overview of the trading partners on our contact page. Further information on data processing, including possible third country transfers, can be found in our data protection information.

Anti-Robot Verification
FriendlyCaptcha ⇗

Inquire

Analog-I/O-Module 0-10V VACUU·BUS® in action

Analog I/O interface module 0-10 V VACUU·BUS, with 2 m VACUU·BUS cable

The Analog-I/O-Module is an analog interface for the VACUU·BUS® system of vacuum measuring gauges and controllers. The input and output signal follows the industry standard of 0-10 V. In the default configuration of the module the actual vacuum value is indicated as a 0-10V output. Therefore the vacuum controllers VACUU·SELECT and CVC 3000 as well as the measuring gauge DCP 3000 can be easily connected to a plotter and used for GMP documentation. Other module configurations allow input and output of vacuum level and motor speed as 0-10V signals. I/O (Input/Output) modules are add-on interfaces for VACUUBRAND gauges and controllers. They are mostly used in process technology, but also in laboratories. Most process data systems work with analog 0-10 V (or 4 to 20 mA) signals or use digital signals, mostly based on 24 V DC. Both signal types are industrial standards and can be provided with these I/O modules. For example in process technology a measured pressure value can be transferred to a PLC via an Analog-I/O-Module. Via a Digital-I/O-Module a start/stop signal from a PLC can be sent to a vacuum controller in order to control a connected pump. In laboratories occasionally a chart recorder is used for documentation purposes. Using an Analog-I/O-Module a pressure signal can be transferred to a 0-10 V signal and used as input to a chart recorder. The I/O modules are connectable with VACUU·BUS® compatible vacuum gauges and controllers which can also be used for I/O module configuration.


Technical data and graphs

Items supplied Analog-I/O-Module 0-10V VACUU·BUS® complete with cable VACUU·BUS® 2m.

Downloads

Analog I/O interface module0-10 V VACUU·BUS,with 2 m VACUU·BUS cable
VACUU·BUS®
Analog-I/O-Module 0-10V VACUU·BUS®
Manual accessories
Manual PDF 7.8 MB 7.7 MB 7.1 MB
Download Download Download

Analog-I/O-Module 0-10V VACUU·BUS® in action

Analog I/O interface module 0-10 V VACUU·BUS, with 2 m VACUU·BUS cable

The Analog-I/O-Module is an analog interface for the VACUU·BUS® system of vacuum measuring gauges and controllers. The input and output signal follows the industry standard of 0-10 V. In the default configuration of the module the actual vacuum value is indicated as a 0-10V output. Therefore the vacuum controllers VACUU·SELECT and CVC 3000 as well as the measuring gauge DCP 3000 can be easily connected to a plotter and used for GMP documentation. Other module configurations allow input and output of vacuum level and motor speed as 0-10V signals. I/O (Input/Output) modules are add-on interfaces for VACUUBRAND gauges and controllers. They are mostly used in process technology, but also in laboratories. Most process data systems work with analog 0-10 V (or 4 to 20 mA) signals or use digital signals, mostly based on 24 V DC. Both signal types are industrial standards and can be provided with these I/O modules. For example in process technology a measured pressure value can be transferred to a PLC via an Analog-I/O-Module. Via a Digital-I/O-Module a start/stop signal from a PLC can be sent to a vacuum controller in order to control a connected pump. In laboratories occasionally a chart recorder is used for documentation purposes. Using an Analog-I/O-Module a pressure signal can be transferred to a 0-10 V signal and used as input to a chart recorder. The I/O modules are connectable with VACUU·BUS® compatible vacuum gauges and controllers which can also be used for I/O module configuration.