PC 3012 NT VARIO select DUOVARIO® chemistry pumping unit

Overview

  • VACUU·SELECT vacuum controller with graphical user interface and predefined applications easy to integrate via digital or analogue interfaces
  • automatic boiling point detection and adjustment of the vacuum for short process times
  • meets high vacuum requirements for very large quantities of most high boiling solvents
  • extraordinary diaphragm life for minimum operational and servicing costs
  • excellent environmental compatibility through low energy consumption, no operating fluid needs (oil, water) and efficient solvent recovery

Ultimate vacuum

1.5 mbar

Ultimate vacuum with gas ballast

3 mbar

Max. pumping speed 50 Hz

28 m3/h

Articleno. 22615741
On demand

Inquire

VARIO® chemistry pumping unit in action

The VARIO® DUO pumping units are consisting of a combination of two individual VARIO® pumping units, connected in parallel on the suction side and driven synchronously by one vacuum controller VACUU·SELECT. The vacuum is controlled accurately. The speed of the two individual pumps is exactly adjusted to the vacuum needs. The controller allows both fully automatic distillations without any user pre-settings as well as specific and reproducible program sequences. The integration into existing control systems via digital and analog interfaces is also possible. The consequent design to highest chemical resistance provides the ideal prerequisite for universal use in chemistry and pharmacy - without any operating fluid such as water or oil. The unique combination of high chemical resistance, very good ultimate vacuum and high pumping speed with low energy consumption and without any operating fluid makes the new VARIO® DUO pumping units the contemporary vacuum source for many applications in the range of kilo-lab, pilot and small productions. They are also used as network pumping units for larger VACUU·LAN® - installations or as an environmentally friendly alternative to existing central vacuum systems. The VARIO® control provides the required vacuum all the time and automatically adjusts the speed of the two pumps to the needs. This results in prolonged maintenance intervals in addition. The low noise level allows placement within the workspace.


Information on the disposal of old devices »
 

Technical data and graphs

Max. pumping speed 50 Hz 28 m3/h Select diagram
Max. pumping speed 60 Hz 16.5 cfm Select diagram
Ultimate vacuum 1.5 mbar / 1.1 torr
Ultimate vacuum with gas ballast 3 mbar / 2.2 torr
Number of heads 16
Number of stages 3
Vacuum controller VACUU·SELECT
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Max. back pressure (abs.) 1.1 bar
Inlet connection Small flange KF DN 25 / hose nozzle DN 15 mm
Outlet connection 2 x hose nozzle DN 10 mm
Coolant connection 4 x hose nozzle DN 6-8 mm
Rated motor power 1.06 kW
Protection class IEC 60529 IP 40
Dimension L in mm 612 mm
Dimension B in mm 925 mm
Dimension H in mm 585 mm
Weight 65 kg
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) 53 dBA
ATEX conformity II 3/- G Ex h IIC T3 Gc X Internal Atm. only
NRTL certification No
Items supplied Pumping unit completely mounted, ready for use, with manual.
Rated mains voltage range 1 200-230 V
Mains frequency 1 50-60 Hz

vac_pumpingspeedm3 für Zoom klicken

Max. pumping speed 50 Hz

vac_pumpingspeedcfm für Zoom klicken

Max. pumping speed 60 Hz

vac_pumpingcurve50 für Zoom klicken

Pump down graph 50 Hz (100 l volume)

vac_pumpingcurve60 für Zoom klicken

Pump down graph 60 Hz (100 l volume)

Downloads

VARIO chemistry pumping unit,PC 3012 NT VARIO select DUO,200-230V / 50-60Hz, without mains cable
PC 3012 NT VARIO select DUO VARIO® chemistry pumping unit
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual vacuum pump
Manual PDF 23 MB 23.4 MB 23 MB
Download Download Download
Manual vacuum gauge / controller
Manual PDF 17.8 MB 17.5 MB 17.5 MB
Download Download Download
Brochure
Brochure PDF 2 MB 2 MB
Download Download
Technical data sheet
Data sheet PDF 2.3 MB 2.3 MB 2.3 MB 2.3 MB 2.4 MB
Download Download Download Download Download

Equipment

This might also interest you

VARIO® chemistry pumping unit in action

The VARIO® DUO pumping units are consisting of a combination of two individual VARIO® pumping units, connected in parallel on the suction side and driven synchronously by one vacuum controller VACUU·SELECT. The vacuum is controlled accurately. The speed of the two individual pumps is exactly adjusted to the vacuum needs. The controller allows both fully automatic distillations without any user pre-settings as well as specific and reproducible program sequences. The integration into existing control systems via digital and analog interfaces is also possible. The consequent design to highest chemical resistance provides the ideal prerequisite for universal use in chemistry and pharmacy - without any operating fluid such as water or oil. The unique combination of high chemical resistance, very good ultimate vacuum and high pumping speed with low energy consumption and without any operating fluid makes the new VARIO® DUO pumping units the contemporary vacuum source for many applications in the range of kilo-lab, pilot and small productions. They are also used as network pumping units for larger VACUU·LAN® - installations or as an environmentally friendly alternative to existing central vacuum systems. The VARIO® control provides the required vacuum all the time and automatically adjusts the speed of the two pumps to the needs. This results in prolonged maintenance intervals in addition. The low noise level allows placement within the workspace.


Information on the disposal of old devices »
 

Technical data and graphs

Max. pumping speed 50 Hz 28 m3/h Select diagram
Max. pumping speed 60 Hz 16.5 cfm Select diagram
Ultimate vacuum 1.5 mbar / 1.1 torr
Ultimate vacuum with gas ballast 3 mbar / 2.2 torr
Number of heads 16
Number of stages 3
Vacuum controller VACUU·SELECT
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Max. back pressure (abs.) 1.1 bar
Inlet connection Small flange KF DN 25 / hose nozzle DN 15 mm
Outlet connection 2 x hose nozzle DN 10 mm
Coolant connection 4 x hose nozzle DN 6-8 mm
Rated motor power 1.06 kW
Protection class IEC 60529 IP 40
Dimension L in mm 612 mm
Dimension B in mm 925 mm
Dimension H in mm 585 mm
Weight 65 kg
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) 53 dBA
ATEX conformity II 3/- G Ex h IIC T3 Gc X Internal Atm. only
NRTL certification No
Items supplied Pumping unit completely mounted, ready for use, with manual.
Rated mains voltage range 1 200-230 V
Mains frequency 1 50-60 Hz

vac_pumpingspeedm3 für Zoom klicken

Max. pumping speed 50 Hz

vac_pumpingspeedcfm für Zoom klicken

Max. pumping speed 60 Hz

vac_pumpingcurve50 für Zoom klicken

Pump down graph 50 Hz (100 l volume)

vac_pumpingcurve60 für Zoom klicken

Pump down graph 60 Hz (100 l volume)

Downloads

VARIO chemistry pumping unit,PC 3012 NT VARIO select DUO,200-230V / 50-60Hz, without mains cable
PC 3012 NT VARIO select DUO VARIO® chemistry pumping unit
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual vacuum pump
Manual PDF 23 MB 23.4 MB 23 MB
Download Download Download
Manual vacuum gauge / controller
Manual PDF 17.8 MB 17.5 MB 17.5 MB
Download Download Download
Brochure
Brochure PDF 2 MB 2 MB
Download Download
Technical data sheet
Data sheet PDF 2.3 MB 2.3 MB 2.3 MB 2.3 MB 2.4 MB
Download Download Download Download Download

Equipment

This might also interest you