Cerabar PMP21 KF DN 16Vacuum sensor

Overview

  • with ATEX certification: II 2G Ex ia IIC T4 Gb
  • Measuring range 1000-1 mbar
  • Accuracy: better than +-3 mbar
Articleno. 20635424
On demand

Inquire

Vacuum sensor in action

Technical data and graphs

Upper measuring limit in mbar/hPa 1000 mbar
Upper measuring limit in torr 750 torr
Lower measuring limit in mbar/hPa 1
Lower measuring limit in torr 1 torr
Measurement principle Edelstahl-Membran (1.4435), gasartunab., Absolutdruck
Accuracy of measurement < +- 3 mbar mbar/hPa/torr
Vacuum sensor 11
Vacum connection small flange KF DN 16
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Metall housing
Protection class IEC 60529 IP 65
Protection class front side IEC 60529 6
Interface 4 - 20 mA
NRTL certification No
ATEX conformity II 2G Ex ia IIC T4 Gb
Items supplied Vacuum sensor for hazardous areas complete with small flange KF DN 16 and plug for cable assembly.

Downloads

ATEX Vacuum gauge head CERABAR PMP21,Endress+Hauser, with KF DN 16,measuring range: 1000-1 mbaraccuracy: better than +-3 mbar,with ATEX approval: II 2G Ex ia IIC T4 Gboutput signal 4 - 20 mA, for operationwith Ex i - p
Cerabar PMP21 KF DN 16 Vacuum sensor
Technical data sheet
Data sheet PDF 0.9 MB 0.9 MB 0.9 MB 0.9 MB 1 MB
Download Download Download Download Download

Technical data and graphs

Upper measuring limit in mbar/hPa 1000 mbar
Upper measuring limit in torr 750 torr
Lower measuring limit in mbar/hPa 1
Lower measuring limit in torr 1 torr
Measurement principle Edelstahl-Membran (1.4435), gasartunab., Absolutdruck
Accuracy of measurement < +- 3 mbar mbar/hPa/torr
Vacuum sensor 11
Vacum connection small flange KF DN 16
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Metall housing
Protection class IEC 60529 IP 65
Protection class front side IEC 60529 6
Interface 4 - 20 mA
NRTL certification No
ATEX conformity II 2G Ex ia IIC T4 Gb
Items supplied Vacuum sensor for hazardous areas complete with small flange KF DN 16 and plug for cable assembly.

Downloads

ATEX Vacuum gauge head CERABAR PMP21,Endress+Hauser, with KF DN 16,measuring range: 1000-1 mbaraccuracy: better than +-3 mbar,with ATEX approval: II 2G Ex ia IIC T4 Gboutput signal 4 - 20 mA, for operationwith Ex i - p
Cerabar PMP21 KF DN 16 Vacuum sensor
Technical data sheet
Data sheet PDF 0.9 MB 0.9 MB 0.9 MB 0.9 MB 1 MB
Download Download Download Download Download