Cerabar PMP21 KF DN 16Vacuum sensor
Overview
- with ATEX certification: II 2G Ex ia IIC T4 Gb
- Measuring range 1000-1 mbar
- Accuracy: better than +-3 mbar
Articleno.
20635424
Vacuum sensor in action
Technical data and graphs
Upper measuring limit in mbar/hPa | 1000 mbar | |
Upper measuring limit in torr | 750 torr | |
Lower measuring limit in mbar/hPa | 1 | |
Lower measuring limit in torr | 1 torr | |
Measurement principle | Edelstahl-Membran (1.4435), gasartunab., Absolutdruck | |
Accuracy of measurement | < +- 3 mbar mbar/hPa/torr | |
Vacuum sensor | 11 | |
Vacum connection | small flange KF DN 16 | |
Lower ambient temperature (storage) | -10 °C | |
Upper ambient temperature (storage) | 60 °C | |
Lower ambient temperature (operation) | 10 °C | |
Upper ambient temperature (operation) | 40 °C | |
Max. media temperature for continuous operation | 40 °C | |
Max. media temperature short term | 80 °C | |
Material of outer housing | Metall housing | |
Protection class IEC 60529 | IP 65 | |
Protection class front side IEC 60529 | 6 | |
Interface | 4 - 20 mA | |
NRTL certification | No | |
ATEX conformity | II 2G Ex ia IIC T4 Gb | |
Items supplied | Vacuum sensor for hazardous areas complete with small flange KF DN 16 and plug for cable assembly. |
Downloads
ATEX Vacuum gauge head CERABAR PMP21,Endress+Hauser, with KF DN 16,measuring range: 1000-1 mbaraccuracy: better than +-3 mbar,with ATEX approval: II 2G Ex ia IIC T4 Gboutput signal 4 - 20 mA, for operationwith Ex i - p
Cerabar PMP21 KF DN 16
Vacuum sensor
Vacuum sensor in action
Technical data and graphs
Upper measuring limit in mbar/hPa | 1000 mbar | |
Upper measuring limit in torr | 750 torr | |
Lower measuring limit in mbar/hPa | 1 | |
Lower measuring limit in torr | 1 torr | |
Measurement principle | Edelstahl-Membran (1.4435), gasartunab., Absolutdruck | |
Accuracy of measurement | < +- 3 mbar mbar/hPa/torr | |
Vacuum sensor | 11 | |
Vacum connection | small flange KF DN 16 | |
Lower ambient temperature (storage) | -10 °C | |
Upper ambient temperature (storage) | 60 °C | |
Lower ambient temperature (operation) | 10 °C | |
Upper ambient temperature (operation) | 40 °C | |
Max. media temperature for continuous operation | 40 °C | |
Max. media temperature short term | 80 °C | |
Material of outer housing | Metall housing | |
Protection class IEC 60529 | IP 65 | |
Protection class front side IEC 60529 | 6 | |
Interface | 4 - 20 mA | |
NRTL certification | No | |
ATEX conformity | II 2G Ex ia IIC T4 Gb | |
Items supplied | Vacuum sensor for hazardous areas complete with small flange KF DN 16 and plug for cable assembly. |
Downloads
ATEX Vacuum gauge head CERABAR PMP21,Endress+Hauser, with KF DN 16,measuring range: 1000-1 mbaraccuracy: better than +-3 mbar,with ATEX approval: II 2G Ex ia IIC T4 Gboutput signal 4 - 20 mA, for operationwith Ex i - p
Cerabar PMP21 KF DN 16
Vacuum sensor