VACUU·SELECTComplete controller built-in version

Overview

  • supplied complete and ready for use, including integrated valve and common hose connections
  • predefined vacuum applications and automatic boiling point detection saves time
  • simple setup - connect VACUU·SELECT in-line between pump and vacuum application
  • integrated vent valve allows inert gas connection
  • integrated check valve minimizes interaction with other applications on the same vacuum supply
Articleno. 20700060
On demand

Inquire

Complete controller built-in version in action

The VACUU·SELECT complete controller provides enhanced process efficiency to applications supported by a vacuum source such as a basic pump or a powerful vacuum network. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run pre-defined applications at the touch of a button, or create your own application with simple drag-and-drop editing. The controller is available as a benchtop unit, ready for mounting on lab scaffolding, or as a built-in version for lab casework. The integrated controller includes the VACUU·SELECT vacuum controller, a check valve, and a chemical-resistant solenoid isolation valve. The ceramic vacuum sensor and venting valve are built right into the body of the VACUU·SELECT controller. The compact unit is easy to install and setup. With its intuitive, application-based interface, the controller offers predefined vacuum processes for all common laboratory applications. In the case of solvent evaporation, it detects the boiling pressure and then holds the pressure level stable using two-point control.


Information on the disposal of old devices »

Technical data and graphs

Upper measuring limit in mbar/hPa 1080 mbar
Upper measuring limit in torr 810 torr
Lower measuring limit in mbar/hPa 0.1
Lower measuring limit in torr 0.1 torr
Measurement principle Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
Accuracy of measurement < +- 1 mbar/hPa/torr / +- 1 digit (after adjustment, constant temp.) mbar/hPa/torr
Vacuum sensor VACUU·SELECT Sensor
Temperature coefficient < 0.15 mbar/hPa/0.11 torr /K mbar/hPa/torr /K
Vacum connection PTFE tubing connection 10/8 mm
Venting valve Integrated, hose nozzle DN 4-5 mm
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 40
Protection class UL50E Type 1
Protection class front side IEC 60529 IP 41
Protection class UL50E front side Type 2
Dimension L in mm 152 mm
Dimension B in mm 126 mm
Dimension H in mm 108 mm
Weight 1.3 kg
Max. current for VACUU BUS (24V DC) 4 A
Cable length connection in m 2 m
Interface Ethernet (RJ45): Modbus TCP / USB (Type A): Data transfer, software update, RS-232 (additional adapter required)
NRTL certification Yes
ATEX conformity II 3/- G Ex h IIC T4 Gc X Internal Atm. only
Items supplied VACUU·SELECT complete controller build-in version, for VACUU·LAN work stations, with solenoid valve, non-return valve, integrated ceramic diaphragm vacuum sensor and venting valve. With power supply, ready to use, with manual.

Downloads

VACUU·SELECT complete controllerbuilt-in version, for VACUU·LAN work stations,with solenoid valve, PVDF/fluoroplastics,100-230V / 50-60Hz, plug CEE/CH/UK/US/AUS/CN
VACUU·SELECT Complete controller built-in version
Manual vacuum gauge / controller
Manual PDF 17.3 MB 17.6 MB 17.6 MB 17.5 MB 17.6 MB 17.6 MB 17.5 MB 17.6 MB 17.6 MB 17.9 MB 17.6 MB 17.7 MB
Download Download Download Download Download Download Download Download Download Download Download Download
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual interface
Manual PDF 1.8 MB 1.8 MB
Download Download
Manual function extension
Manual PDF 11.6 MB 11.4 MB
Download Download
Technical data sheet
Data sheet PDF 1.5 MB 1.5 MB 1.5 MB 1.5 MB 1.6 MB
Download Download Download Download Download

Equipment

This might also interest you

Complete controller built-in version in action

The VACUU·SELECT complete controller provides enhanced process efficiency to applications supported by a vacuum source such as a basic pump or a powerful vacuum network. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run pre-defined applications at the touch of a button, or create your own application with simple drag-and-drop editing. The controller is available as a benchtop unit, ready for mounting on lab scaffolding, or as a built-in version for lab casework. The integrated controller includes the VACUU·SELECT vacuum controller, a check valve, and a chemical-resistant solenoid isolation valve. The ceramic vacuum sensor and venting valve are built right into the body of the VACUU·SELECT controller. The compact unit is easy to install and setup. With its intuitive, application-based interface, the controller offers predefined vacuum processes for all common laboratory applications. In the case of solvent evaporation, it detects the boiling pressure and then holds the pressure level stable using two-point control.


Information on the disposal of old devices »

Technical data and graphs

Upper measuring limit in mbar/hPa 1080 mbar
Upper measuring limit in torr 810 torr
Lower measuring limit in mbar/hPa 0.1
Lower measuring limit in torr 0.1 torr
Measurement principle Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
Accuracy of measurement < +- 1 mbar/hPa/torr / +- 1 digit (after adjustment, constant temp.) mbar/hPa/torr
Vacuum sensor VACUU·SELECT Sensor
Temperature coefficient < 0.15 mbar/hPa/0.11 torr /K mbar/hPa/torr /K
Vacum connection PTFE tubing connection 10/8 mm
Venting valve Integrated, hose nozzle DN 4-5 mm
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 40
Protection class UL50E Type 1
Protection class front side IEC 60529 IP 41
Protection class UL50E front side Type 2
Dimension L in mm 152 mm
Dimension B in mm 126 mm
Dimension H in mm 108 mm
Weight 1.3 kg
Max. current for VACUU BUS (24V DC) 4 A
Cable length connection in m 2 m
Interface Ethernet (RJ45): Modbus TCP / USB (Type A): Data transfer, software update, RS-232 (additional adapter required)
NRTL certification Yes
ATEX conformity II 3/- G Ex h IIC T4 Gc X Internal Atm. only
Items supplied VACUU·SELECT complete controller build-in version, for VACUU·LAN work stations, with solenoid valve, non-return valve, integrated ceramic diaphragm vacuum sensor and venting valve. With power supply, ready to use, with manual.

Downloads

VACUU·SELECT complete controllerbuilt-in version, for VACUU·LAN work stations,with solenoid valve, PVDF/fluoroplastics,100-230V / 50-60Hz, plug CEE/CH/UK/US/AUS/CN
VACUU·SELECT Complete controller built-in version
Manual vacuum gauge / controller
Manual PDF 17.3 MB 17.6 MB 17.6 MB 17.5 MB 17.6 MB 17.6 MB 17.5 MB 17.6 MB 17.6 MB 17.9 MB 17.6 MB 17.7 MB
Download Download Download Download Download Download Download Download Download Download Download Download
Safety information for vacuum equipment
Manual PDF 5.4 MB
Multilingual Download
Manual interface
Manual PDF 1.8 MB 1.8 MB
Download Download
Manual function extension
Manual PDF 11.6 MB 11.4 MB
Download Download
Technical data sheet
Data sheet PDF 1.5 MB 1.5 MB 1.5 MB 1.5 MB 1.6 MB
Download Download Download Download Download

Equipment

This might also interest you