Product description

CVC 3000E

Vacuum controller

The CVC 3000 manages vacuum processes by controlling vacuum pumps, vacuum and coolant valves and accessories. The illuminated graphical display with clear text menus (14 languages) and the jog wheel make its handling nearly self-explanatory. Depending on the model, a ceramic diaphragm vacuum sensor and venting valve are already integrated (or externally connectable). The ceramic vacuum sensor is chemically highly resistant, measures gas-type independent and accurately. This controller offers a two-point vacuum control mode via in-line solenoid valve. Ten fully configurable programs (with up to ten time and pressure steps each, and control functions such as venting and pumping) can be easily edited and stored. External valves and sensors for liquid level and vacuum down to the fine vacuum range are easy to connect and recognized automatically via the VACUU·BUS® control system. Besides the CVC 3000 enables the measurement of relative pressure with regard to a reference sensor (VSK 3000).

Information on the disposal of old devices »

Accessories and spare parts
DN 8 mm Vacuum tubing transparent
20686061
Upon request
Technical Data

Technical data

Item number 20635027
Upper measuring limit in mbar/hPa 1080 mbar
Upper measuring limit in torr 810 torr
Lower measuring limit in mbar/hPa 0.1 mbar
Lower measuring limit in torr 0.1 torr
Upper control limit in mbar/hPa 1060
Upper control limit in torr 795
Lower control limit in mbar/hPa 0.1
Lower control limit in torr 0.1
Measurement principle Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
Accuracy of measurement < +- 1 mbar/hPa/torr / +- 1 digit (after adjustment, constant temp.) mbar/hPa/torr
Vacuum sensor Integrated
Temperature coefficient < 0.07 mbar/hPa/0.05 torr /K mbar/hPa/torr /K
Vacum connection PTFE tubing connection 10/8 mm
Venting valve Integrated, hose nozzle DN 4-5 mm
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 20
Protection class UL50E Type 1
Protection class front side IEC 60529 IP 42
Dimension L in mm 123 mm
Dimension W in mm 124 mm
Dimension H in mm 83 mm
Weight 0.44 kg
Max. current for VACUU BUS (24V DC) 4 A
Cable length connection in m 2 m
Interface RS 232C
NRTL certification Yes
ATEX conformity II 3/- G Ex h IIC T3 Gc X Internal Atm. only
Items supplied CVC 3000 for installation
Items supplied
CVC 3000 for installation
Downloads

Overview Downloads

image
Technical Data Sheet | PDF | 6.9 MB 6.9 MB 6.9 MB 6.9 MB 7 MB
image
Manual vacuum gauge / controller
Download download Download download Download download
Manual vacuum gauge / controller | PDF | 20.6 MB 20.7 MB 22 MB
image
Safety information
Multilingual Download download